Main technical parameters
Valve function | 4V1 | 4V2 | 4V3 |
Reset mode: gas reset | 是 | ||
Return mode: mechanical spring return | 是 | ||
Air port 1 vacuum operation | When using an external leader | ||
设计 | Piston slide valve | ||
Sealing principle | 软性 | ||
Driving mode | 电气 | ||
Control mode | 先导 | ||
Pilot gas source | 外部 | ||
Exhaust function | Tape flow control | ||
Manual device | Optional non-locking type | ||
Installation mode | Installed on the air path plate | ||
Installation position | 任意 | ||
Switch position display | LED | ||
气口 1,3,5,12/14,82/84 | On the pavement | ||
气口 2,4 | G¼ | ||
Product weight [g] | 175 | 320 | 400 |
Working and environmental conditions | |||
Valve function | 20 | 10 | 30 |
Working medium | Compressed air, according to ISO 8573-1:2010 [7:4:4] | ||
Pilot medium | Compressed air, according to ISO 8573-1:2010 [7:4:4] | ||
Description of working media/pilot media | Lubricated (once used, must always be lubricated) | ||
Working pressure internal leader [bar] | 1.5 … 8 | 1.5 … 8 | 3 … 8 |
Working pressure external leader [bar] | -0.9 … 10 | -0.9 … 8 | -0.9 … 10 |
Pilot pressure4) [bar] | 1.5 … 8 | 3 … 8 | 3 … 8 |
Ambient temperature [°C] | –5 … +60 | ||
Medium temperature [°C] | –5 … +60 | ||
Electrical parameter | |||
Electrical connection | Via E-box | ||
Operating voltage [V DC] | 24 ±10% | ||
Power consumption [W] | 1 | ||
Continuous conductivity ED [%] | 100 | ||
Maximum switching frequency [Hz] | 3 | ||
Protection class, in accordance with EN 60529 | IP67 | ||
Valve switching time | |||
Valve function | 20 | 10 | 30 |
Switch time on [ms] | - | 13 | 20 |
Switch time off [ms] | - | 50 | 57 |
Conversion time [ms] | 15 | - | 31 |